ποΈGitΠ―ΡΠ°ποΈ
docs/ru-rRU/user/telemetry-and-sensors.md renovate/net.java.dev.jna-jna-5.x (5a8f4966) Text, 5.70 KB
title: Telemetry & Sensors
parent: Π ΡΠΊΠΎΠ²ΠΎΠ΄ΡΡΠ²ΠΎ ΠΏΠΎΠ»ΡΠ·ΠΎΠ²Π°ΡΠ΅Π»Ρ
nav_order: 9
last_updated: 2026-05-13
description: Sensor data on the mesh β supported environment, air quality, and power sensors, plus configuration and viewing guides.
aliases:
β’ sensors
β’ environment
β’ weather
β’ power-metrics
Telemetry & Sensors
Meshtastic nodes can collect and share sensor data across the mesh network.
ΠΠ±Π·ΠΎΡ
Telemetry allows nodes equipped with sensors to broadcast environmental, power, and device health information. This data is visible on the node detail screen and can be logged over time.
Device Telemetry
All Meshtastic nodes report basic device telemetry:
ββββββββββββββββββββββββ¬βββββββββββββββββββββββββββββββββ¬ββββββββββββββββββ
β Metric β ΠΠΏΠΈΡΠ°Π½ΠΈΠ΅ β Typical Range β
ββββββββββββββββββββββββΌβββββββββββββββββββββββββββββββββΌββββββββββββββββββ€
β Battery Level β Charge percentage β 0β100% β
β ΠΠ°ΠΏΡΡΠΆΠ΅Π½ΠΈΠ΅ β Battery voltage β 3.0β4.2V (LiPo) β
β ΠΡΠΏΠΎΠ»ΡΠ·ΠΎΠ²Π°Π½ΠΈΠ΅ ΠΊΠ°Π½Π°Π»Π° β % of airtime used locally β 0β100% β
β Air Utilization TX β % of airtime used by this node β 0β100% β
β ΠΠΏΡΠ°ΠΉΠΌ β Seconds since last boot β Varies β
ββββββββββββββββββββββββ΄βββββββββββββββββββββββββββββββββ΄ββββββββββββββββββ
Environment Sensors
Supported environmental sensors:
Temperature & Humidity
βββββββββββ¬ββββββββββββββ¬ββββββββββββ¬βββββββββββ¬ββββββββββββββββββββββββββ
β Sensor β Π’Π΅ΠΌΠΏΠ΅ΡΠ°ΡΡΡΠ° β ΠΠ»Π°ΠΆΠ½ΠΎΡΡΡ β ΠΠ°Π²Π»Π΅Π½ΠΈΠ΅ β ΠΠ°ΠΌΠ΅ΡΠΊΠΈ β
βββββββββββΌββββββββββββββΌββββββββββββΌβββββββββββΌββββββββββββββββββββββββββ€
β BME280 β β β β β β β Recommended all-in-one β
β BME680 β β β β β β β Adds gas resistance/IAQ β
β SHT31 β β β β β β β High accuracy β
β MCP9808 β β β β β β β Precision temperature β
β LPS22 β β β β β β β Pressure only β
βββββββββββ΄ββββββββββββββ΄ββββββββββββ΄βββββββββββ΄ββββββββββββββββββββββββββ
Air Quality
ββββββββββββ¬βββββββββββββββββββββββββββββββ¬βββββββββββββββββββββββββββββ
β Sensor β Metric β ΠΠ°ΠΌΠ΅ΡΠΊΠΈ β
ββββββββββββΌβββββββββββββββββββββββββββββββΌβββββββββββββββββββββββββββββ€
β BME680 β Gas Resistance / IAQ β Volatile organic compounds β
β PMSA003I β PM1.0, PM2.5, PM10 β Particulate matter β
β SEN55 β PM, NOx, VOC, Temp, Humidity β Multi-sensor β
ββββββββββββ΄βββββββββββββββββββββββββββββββ΄βββββββββββββββββββββββββββββ
Light & UV
ββββββββββββ¬ββββββββββββββββββββββ
β Sensor β Metric β
ββββββββββββΌββββββββββββββββββββββ€
β OPT3001 β Ambient light (lux) β
β VEML7700 β Ambient light (lux) β
β LTR390 β UV index β
ββββββββββββ΄ββββββββββββββββββββββ
ΠΠ΅ΡΡΠΈΠΊΠΈ ΠΏΠΈΡΠ°Π½ΠΈΡ
Nodes with INA-series power sensors can report:
βββββββββββββββ¬βββββββββββββββββββββββββ
β Metric β ΠΠΏΠΈΡΠ°Π½ΠΈΠ΅ β
βββββββββββββββΌβββββββββββββββββββββββββ€
β Bus Voltage β Supply rail voltage β
β Π’ΠΎΠΊ β Power consumption (mA) β
β ΠΠΈΡΠ°Π½ΠΈΠ΅ β Calculated power (mW) β
βββββββββββββββ΄βββββββββββββββββββββββββ
Useful for monitoring solar charging or battery health on remote nodes.
Configuring Telemetry
1. Navigate to Settings β Module Config β Telemetry.
2. Set reporting intervals:
β’ Device Metrics Interval β how often to broadcast device metrics
β’ Environment Metrics Interval β how often to broadcast sensor data
3. Enable specific sensor types as needed.
Recommended Intervals
βββββββββββββββββββββββββββ¬βββββββββββββ¬ββββββββββββββββββ
β Use Case β Device (s) β Environment (s) β
βββββββββββββββββββββββββββΌβββββββββββββΌββββββββββββββββββ€
β Urban mesh (many nodes) β 3600 β 3600 β
β Rural mesh (few nodes) β 900 β 900 β
β Weather station β 900 β 300 β
β Battery conservation β 7200 β 7200 β
βββββββββββββββββββββββββββ΄βββββββββββββ΄ββββββββββββββββββ
β β οΈ Note: Shorter intervals increase airtime usage and battery drain across the mesh.
Viewing Telemetry
1. Navigate to Nodes and select a node.
2. Telemetry sections show on the detail screen:
β’ Device Metrics (always available)
β’ Environment Metrics (if sensors present)
β’ Power Metrics (if INA sensor present)
3. Historical graphs show trends over time.
Troubleshooting
β’ No environment data showing? The remote node needs a physical sensor connected (e.g., BME280 on I2C). Device telemetry (battery, uptime) is always available, but environment metrics require hardware.
β’ Stale readings? Check the reporting interval β very long intervals (7200s+) mean data updates infrequently. Also verify the remote node is still online.
β’ Sensor conflict on I2C bus? Some sensors share I2C addresses. If you have multiple sensors on the same bus, check for address collisions in the radio's serial debug output.
Related Topics
β’ Node Metrics β view telemetry data on the node detail screen
β’ Settings β Modules & Admin β telemetry module configuration
β’ Units & Locale β temperature and pressure display units
Served by rngit 1.4.2 - Generated in 0.06s